  Datasheet File OCR Text:
  specification model dc voltage rated current current range rated power peak current peak power note.6 output voltage adj. range line regulation load regulation setup, rise time hold up time (typ.) voltage range frequency range efficiency (typ.) note.8 input inrush current (typ.) leakage current over temperature safety standards working temp. note.5 dc ok realy contact ratings (max.) working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage ac current (typ.) 1500ms, 60ms/230vac 30 at full load 00ms, 60ms/115vac 20ms/230vac 20ms/115vac at full load 88 ~ 264vac 124 ~ 370vdc 47 ~ 63hz 94% 0.93/230vac 0.99/115vac at full load 2.6a/115vac 1.3a/230vac 56 ~ 65v 33a/115vac 65a/230vac <1ma / 240vac normally w more than 3 and then shut down o/p voltage with auto-recovery orks within 110 ~ 150% rated output power for seconds 29 ~ 33v >150% rated power, constant current limiting with auto-recovery wit hin 2 seconds and may cause to shut down if over 2 seconds protection type : shut down o/p voltage with auto-recovery 95 5 (tsw : detect on heatsink of power switch) protection type : shut down o/p voltage, recovers automatically after t emperature goes down ul508 tuv en60950-1 approved , compliance to en55022 (cispr22) class b, en61000-3-2,-3 compliance to en61000-4-2,3,4,5,6,8,11, en55024, en61000-6- 2 (en50082-2), en61204-3, heavy industry level, criteria a, semi f47, gl approved -25 ~ +70 (refer to "derating curve") 60vdc/0.3a, 30vdc/1a, 30vac/0.5a resistive load 20 ~ 95% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 50 component:10 ~ 500hz, 2g 10min./1cycle, 60min. each along x, y, z axes; mo unting: compliance to iec60068-2-6 169.3khrs min. mil-hdbk-217f (25 ) 63*125.2*113.5mm (w*h*d) 1.03kg; 12pcs/13.4kg/1.06cuft power factor (typ.) sdr-240-48 48v 5a 0 ~ 5a 240w 7.5a 120mvp-p 48 ~ 55v 1.0% 0.5% 1.0% sdr-240-24 24v 10a 0 ~ 10a 240w 15a 360w (3sec.) 100mvp-p 24 ~ 28v 1.0% 0.5% 1.0% features : sdr-240 series withstand voltage isolation resistance i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac o/p-dc ok:0.5k vac i/p-o/p, i/p-fg, o/p-fg:>100m ohms / 500vdc / 25 / 70% rh environment safety & function emc (note 4) protection ripple & noise (max.) note.2 voltage tolerance note.3 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 5. installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and r ight side are recommended when loaded permanently with full power. in case the adjacent device is a heat source, 15mm clearance is recommended . 6. 3 seconds max., please refer to peak loading curves. 7. derating may be needed under low input voltage. please check the deratin g curve for more details. 8. after 30 minutes of burn-in. 240w single output industrial din rail with pfc function gl high efficiency 94% and low power dissipationbuilt-in active pfc function, pf>0.93 protections: short circuit / overload / over voltage / over temperature cooling by free air convection can be installed on din rail ts-35/7.5 or 15 ul 508 (industrial control equipment) approved en61000-6-2(en50082-2) industrial immunity level 100% full load burn-in test 3 years warranty 150% peak load capabilitybuilt-in dc ok relay contact pq s e m i f 4 7 file name:sdr-240-spec 2011-08-23 emc immunity emc emission
mechanical specification file name:sdr-240-spec 2011-08-23 block diagram case no. 979a unit:mm dc ok relay contact detection pwm & pfc circuit o.l.p. u.v.p. emi filter rectifiers power switching filter & rectifiers +v dc ok -v i/p fg control o.v.p. & o.c.p. pfc circuit pfc control terminal pin no. assignment (tb1) terminal pin no. assignment (tb2) pin no. pin no. 1 1,2 2 3,4 5,6 3 assignment assignment fg ac/l ac/n dc output +v dc output -v admissible din-rail:ts35/7.5 or ts35/15 35 63 12 3 4 5 6 12 3 125.2 113.5 tb1 tb2 dc ok dc ok +v adj. relay contact + contact close psu turns on / dc ok. psu turns off / dc fail. 30v/1a resistive load. contact open contact ratings (max.) sdr-240 series 240w single output industrial din rail with pfc function
360w 120w 10 sec. 3 sec. file name:sdr-240-spec 2011-08-23 sdr-240 series 240w single output industrial din rail with pfc function input voltage (v) 60hz load (%) ambient temperature ( ) load (%) -25 0 continuous for 3 sec. (typ.) 10 20 30 40 50 60 70 60 75 100 112.5 150 100 40 88 110 50 60 70 80 155 135 230 264 90 100 (vertical) output derating vs input voltage derating curve peak loading 360w ( 1 ) ( 2 ) 240w 100 sec. 3 sec.


▲Up To Search▲   

 
Price & Availability of SDR-24011

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X